Hoymk AMR-10DD DC-DC 10A Actually 3-32V DC to 5-220V DC AMR 10DD Single Phase Solid State Relay
Product Features:
1, TRIAC Output,Zero Voltage Opens, Zero Current Turnoff;
2, Optical Isolation between the Input Loop and Output Loop;
3, Dielectric Strength 2500V between Input-Output;
4, 100% Load Current Aging Test.
This is Solid State Relay AMR-10DD DC-DC 10A
Control: DC Control DC
Load Voltage :5-220VDC
Control Voltage 3-32VDC
Current DC:3-25mA
-State Leakage Current: 2mA
-State Pressure 1.5VAC
Off Time 10mS
Dielectric Withstand Voltage :2500VAC
Insulation Resistance: 500M /500VDC
Working Temperature:-30 -+ 75
Mounting:Bolts
Indicating:LED
Specification:
Original Box: Yes
Color: As Picture
Weight:132g
Packing Content:
1 x Solid State Relay AMR-10DD
Safety Precautions :
1 , Must be used when the load current is higher than 5A is
mounted on a heat sink or metal base plate with the corresponding
cooling effect , and coated with thermal grease between the SSR Heat
bottom mounting surface , 40A above plus fan forced cooling or water .
2 , Using the AC inductive load , high transient voltages and
inrush current is applied to the output, which may cause the solid state
relay conduction or damaged, usually require access at the output
voltage with a specific clamping voltage control devices, such as double
Zener diode or varistor (MOV). Rated voltage varistor is recommended to
take a 1.6-1.9 times ;
3, The control close to the minimum load current is small current
load shall load a dummy load resistor in parallel to reduce the leakage
current compared to the output of the load high residual voltage.
4, In order to avoid the temperature exceeds the allowable value
of solid-state relays , considering the cooling effect of the
application should be designed and installed position , only when two or
more solid state relays mounted side by side , you should leave
appropriate spacing.
5 , The parallel between the output may not be more than just the
use of solid-state relays , in an attempt to increase the output
current. However, output can be used in tandem in order to apply a
higher operating voltage.
6, When using more than just a solid state relay when shared
control power inputs that can be used in tandem can also be used in
parallel .
7 , Capacitive load caution this piece , please select the capacitive load dedicated solid state relays.
4, In order to avoid the temperature exceeds the allowable value
of solid-state relays , considering the cooling effect of the
application should be designed and installed position , only when two or
more solid state relays mounted side by side , you should leave
appropriate spacing.
5 , The parallel between the output may not be more than just the
use of solid-state relays , in an attempt to increase the output
current. However, output can be used in tandem in order to apply a
higher operating voltage.
6, When using more than just a solid state relay when shared
control power inputs that can be used in tandem can also be used in
parallel .
7 , Capacitive load caution this piece , please select the capacitive load dedicated solid state relays.